SECTORS C5 – CX

Petrochemicals

From structural steel to piping, from storage tanks to process equipment, we have a solution for everything. In this sector, choosing the wrong system creates not just cost but operational risk.

TYPICAL LOAD · Chemical vapour, high temperature, CUI risk

RISK ANALYSIS

This is where corrosion comes from.

  • Chemical vapour and acidic condensation
  • Risk of corrosion under insulation (CUI)
  • Temperature cycling and thermal expansion
  • Limited access due to continuous processes
Protective coating application in the petrochemicals sector
RECOMMENDED SYSTEM

Coating build-up.

The layer build-up typically used in this sector. Values are indicative; the final system is determined by the site inspection report and the product technical data sheet.

PrimerZinc-rich epoxy
80 µm
Intermediate - MidcoatEpoxy High Solids
200 µm
Finish / TopcoatPolyurethane
80 µm
TOTAL DFT360 µm
CATEGORYC5 – CX

Indicative system example.

APPLICATION AREAS

Where is it used?

Process pipelines

Storage tanks

Reactor and column exteriors

Structural steel and platforms

Pump and valve groups

POINTS TO NOTE
  • A CUI-suitable system is essential on surfaces under insulation
  • Observe application temperature limits on hot surfaces
  • The chemical exposure list should be shared with the technical team
FOR YOUR PETROCHEMICALS PROJECT

Let us see the site and choose the system together

Let us assess your existing coating against ISO 12944 and report on the risks and more efficient solutions. The site inspection report is free of charge.

Free site inspection report →